Ports 5001, 5002, 5003 and 5004 on the TimeSource 3600 are used as though they
were serial TL1 communication ports. The following values are set at the factory
and appear at reset:
MONMSG=INH (monitors only the current port for messages)
KEEPALIVE=0 (does not send a COMPLD message to keep connection
open)
ENDOFTEXT=0 (does not include an end-of-text code with a TL1 message)
ECHO=ALW (echoes characters back to the sending terminal)
COMPRI=ALW1 (normal communication, including autonomous messages)
AUTOLOGOFF=0 (does not log off the user during inactivity)
SWCONTROL=INH (uses no flow control)
If these values require change, use the Edit Communications command to set
communications parameters for TL1 communications.
ED-COM::COM-a:<ctag>:::[MONMSG=b[,]][KEEPALIVE=c[,]]
[ENDOFTEXT=d[,]][ECHO=b[,]][COMPRI=e[,]][AUTOLOGOFF=c[,]
][SWCONTROL=b];
COM-a
= User IP port (a = 5001, 5002, 5003 or 5004)
MONMSG=b
= Monitors messages on all ports (b = ALW), or current port
(b = INH)
KEEPALIVE=c
= Inactive minutes until the unit sends a COMPLD message
to keep the connection from being closed (c = 0 to 255)
ENDOFTEXT=d = Hex code added to responses before semicolon (d = 0
(disabled) to 9F)
ECHO=b
= Echoes characters received so they appear on the user’s
screen as typed (b = ALW), or inhibits echo (b = INH)
COMPRI=e
= Sets the communication port capabilities as follows:
ALW0=normal communication, no autonomous messages
ALW1=normal communication, autonomous messages
ALW2=autonomous messages received, logged on or not
INH =closes connection and keeps port from use
(command must come from another port) (if the port is in
use, this command also logs off the user)
AUTOLOGOFF=c = Inactive minutes until the unit logs off the user, keeping the
connection open (c = 0 to 255)
SWCONTROL=b = uses software (XON/XOFF) flow control (b = ALW), or
no flow control (b = INH)
Procedure G. Power Up (cont’d)
Step
Procedure
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...