15
Install the battery source fuse(s) in the rack fuse bay that supplies power to the
TimeSource 3600. The TimeSource 3600 enters its warm-up mode after
approximately 60 s when power is applied. During the warm-up period, the
following conditions exist:
• Status GPS lamp is green
• Status SYS lamp is off
• E1 outputs are squelched, sending AIS (factory setting), or sending an SSM
message, as specified in the ED-EQPT command
• Additional eight E1 outputs (if equipped) are squelched, sending AIS (factory
setting), or sending an SSM message, as specified in the ED-EQPT command
• 10 MHz and 1 pps outputs are on (unreliable while Status SYS lamp is off)
• ESCIU por ts (if equipped) are on (unreliable while Status SYS lamp is off)
Notes:
1. The CRIT lamp and other alarm indication lamps may light. The host computer
may display transient and standing alarm condition messages. Ignore alarms while
the Status SYS lamp is off during warm-up, unless alarms apply to inputs and
outputs that were previously entered.
2. TL1 commands may be entered during warm-up. Inputs and outputs can be
enabled, and system parameters can be set or changed.
Procedure G. Power Up (cont’d)
Step
Procedure
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...