![Symmetricom TimeSource 3600 Manual Download Page 174](http://html.mh-extra.com/html/symmetricom/timesource-3600/timesource-3600_manual_1419630174.webp)
174
TimeSource 3600
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Retrieve Equipment (cont’d)
Response Format:
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>::::<spec_block>"...
/*LINK:<link>,CMD:<command>*/
;
The parameters which may be displayed in the <spec_block> are
listed below.
Aid
Parameter
Value
Parameter Description
TS3600
BYPASS=a
(990-72060-04
systems only)
a = AIS
When the ESCIU detects LOS on an input
span, an all-ones signal (AIS), without the E1
alignment sequence, is output to the
downstream network element
a = PASSTHRU
When the ESCIU detects LOS on an input
span, the LOS alarm signal, with the E1
alignment sequence, is passed through to the
downstream network element
TOD=a
a = CISCO
Serial message sent is Cisco format
a = NTP4
Serial message sent is NTP Type 4 format
a = NONE
No serial message is sent
ALMCOND=a
a = ALW
Alarm conditioning for outputs is enabled
a = INH
Alarm conditioning for outputs is disabled
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...