Wise Package Studio Reference
194
Test Expert
You can configure Machine Capture settings to limit the areas of the computer that are
captured in the snapshot.
See
Machine Capture Settings
on page 169.
Installation tests and uninstall tests do not appear if you opened a cached copy of an
.MSI. Every time a Windows Installer installation is run, a randomly-named copy of the
.MSI is cached in the system directory. The cached copy contains the installation
information and logic, but it does not contain the installation files.
See also:
Created Files Test Case
on page 195
Created Registry Entries Test Case
on page 196
Destroyed Files Test Case
on page 197
Destroyed Registry Entries Test Case
on page 198
Residual Files Test Case
on page 198
Residual Registry Entries Test Case
on page 199
About Test Cases
on page 164
How to Run Uninstall Tests
¾
Quality Assurance module only.
This procedure applies to all uninstall tests.
Note
Uninstall tests do not appear if a group is open.
Before running uninstall tests
1. Click the Install or Install As button that appears on the Test Expert toolbar.
2. Create a pre-installation snapshot with Machine Capture.
3. Install the application.
For details on the preceding steps, see
How to Run Installation Tests
on page 174.
4. Run application execution tests, running the installed application and exercising all
of its functions.
See
How to Run Application Execution Tests
on page 189.
5. If the application was installed into a virtual software layer, verify that the layer is
activated.
To run uninstall tests
1. Close all applications other than Wise Package Studio and Test Expert, including all
background applications and services that might access files and registry entries on
the testing computer.
Files or registry entries created by other applications can interfere with the test
results.
2. After you finish the application execution tests, select any uninstall test in the left
pane and click Uninstall.