4 Guide to the Routine Maintenance Using the System
Monitor Interface
NetBackup 5020
Routine Maintenance
4-14
Symantec Corporation Issue 01 (2010-12-10)
Table 4-5
Description of parameters related to the fan status
Parameter
Description
Status
The fan state.
Device Present
indicates that the fan works normally.
Device Absent
indicates that the fan is faulty.
Speed
The rotational speed of the fan.
The value of the rotational speed ranges between
LowWaterMark
and
HighWaterMark
, that is, between
1,974 RPM
and
11,468RPM
.
LowWaterMark
Lowest value of the fan rotational speed. The value is
1,974 RPM
.
HighWaterMark
Highest value of the fan rotational speed. The value is
11,468 RPM
.
ErrorStatus
Fan status.
If the value of ErrorStatus is
0
, it indicates that a fan is working
normally.
If the value of ErrorStatus is
1
, it indicates that a fan is working
abnormally.
----End
Exception Handling
If the fan is in the
Device Absent
state, see “Fan Running/Alarm Indicator Is Red On” in the
NetBackup 5020 Hardware Troubleshooting
.
4.6 Checking the Power Supply Status
This section describes how to check the power supply status on the system monitoring
interface. By checking the power supply status, you can know whether the power supply
works normally.
Impact on the System
None.
Reference Standard
The normal state of a power supply is
Presence detected
.
Procedure
Step 1
Log in to the system monitoring interface.
For the detailed procedure, see