NetBackup 5020
Routine Maintenance
3 Guide to Routine Maintenance on Equipment Site
Issue 01 (2010-12-10)
Symantec Corporation
3-7
5
Link indicator for the IPMI
management network
interface
6
System alarm/location indicator
7
10GE NIC interface
Table 3-4
Description of the indicators of the rear view of NetBackup 5020
Location
Type
Color
Status
Description
Power
module
Power
running/alarm
indicator
Green
On
The AC power is normal.
Green
Blinking
The AC input is normal,
but the device is not
powered on.
Orange
On
A power alarm occurred.
-
Off
The power module failed
to be powered on or is not
connected to the mains
power supply.
Rear panel
Link indicator of
the IPMI
management
network port
Green
On
The link of the
management network port
is normal.
-
Off
No link.
Active indicator
of the IPMI
management
network port
Orange
Blinking
Data is being transferred.
-
Off
No data is being
transferred.
Link indicator of
the service
network port
(NIC1/NIC2)
Green
On
Data is being transferred
at a rate of 1,000 Mbit/s.
Orange
On
Data is being transferred
at a rate of 100 Mbit/s.
-
Off
Data is being transferred
at a rate of 10 Mbit/s, or
no link.
Active indicator
of service
network port
(NIC1/NIC2)
Yellow
Blinking
Data is being transferred.
-
Off
No data is being
transferred.
Check indicator status of the 10GE NIC