42
SV
104BIS User Manual
Note:
The voice comment can be recorded before or after the measurement run takes place and
linked to the Previous or the Next measurement run. But be beware, that linking to the previous
measurement will not be possible in case when the unit is switched off and on again or there are no
previous logger files. In this case the recording screen will appear (with default linking the comment
to the next logger file).
4.9
B
EFORE AND AFTER MEASUREMENT RUN
Before starting a measurement ensure:
1
the instrument is turned on (Chapter
2
there is sufficient battery operating life and free memory by checking the status screen
(Chapter
3
required configuration setup is selected (Chapter
4
SV 104BIS is calibrated, because it affects the results (Chapter
5
the windscreen is put on because it protects the microphone from industrial environment such
as dust and moisture or from effects of impact (Chapter
).
After stopping the measurement run, make sure:
1
the calibration is still maintained (Chapter
2
the data is properly downloaded to PC for further analysis (Chapter
3
the instrument is turned off (Chapter
).
4.10
S
TARTING AND STOPPING MEASUREMENT RUN
START:
To start measurements the user has to press the
and
keys at the same time. The results of the
measurement are displayed in the last used result’s display view mode. As an
example, ONE RESULT view
mode is displayed. ONE RESULT view mode is always available for most functions of the instrument. The
results of the measurements can also be presented in other view modes, which can be enabled or disabled
and adjusted to the user’s needs.
Figure 4-17
One profile mode screen view
STOP:
The same combination of keys:
and
allows the user to stop the measurement run. All run results
are always saved automatically, there is no need to save them manually.
Note:
The instrument can be started or stopped remotely thru wireless Bluetooth
®
interface. See
Chapter
for mobile application description.
Summary of Contents for SV 104BIS
Page 139: ...139 SV104BIS User Manual 250 Hz 315 Hz 400 Hz 500 Hz...
Page 140: ...140 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Page 141: ...141 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 142: ...142 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Page 143: ...143 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Page 144: ...144 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 148: ...148 SV104BIS User Manual Figure C 4 Total directional characteristics asymmetrical axis...
Page 150: ...150 SV104BIS User Manual 630 Hz 800 Hz 1000 Hz 1250 Hz...
Page 151: ...151 SV104BIS User Manual 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 152: ...152 SV104BIS User Manual 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Page 153: ...153 SV104BIS User Manual 4500 Hz 5000 Hz 5600 Hz 6300 Hz...
Page 154: ...154 SV104BIS User Manual 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 166: ...166 SV104BIS User Manual 1 3 octave filters for 16 0 Hz 1 1 octave filter...
Page 180: ...180 SV104BIS User Manual...