ELECTRICAL SYSTEM 6-15
• Apply a small quantity of THREAD LOCK to the starter motor
housing bolts.
/
99000-32050: THREAD LOCK “1342”
• Apply SUZUKI SUPER GREASE to the O-ring.
-
99000-25010: SUZUKI SUPER GREASE “A”
STARTER RELAY INSPECTION
• Remove the right frame cover. (
!
5-3)
• Disconnect the
-
battery lead wire from the battery.
• Remove the starter relay cover
1
.
• Disconnect the starter relay coupler
2
.
• Disconnect the starter motor lead wire
3
and battery lead
wire
4
.
• Remove the starter relay
5
.
Apply 12 V to
A
and
B
terminals and check for continuity
between the positive and negative terminals using the multi cir-
cuit tester. If the starter relay clicks and continuity is found, the
relay is OK.
#
09900-25008: Multi circuit tester set
+
Tester knob indication: Continuity test (
,
,
,
,
)
"
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
#
09900-25008: Multi circuit tester set
(
Tester knob indication: Resistance (
Ω
Ω
Ω
Ω
)
&
Starter relay resistance: 3 – 6
Ω
Ω
Ω
Ω
Do not apply a battery voltage to the starter relay for
more than five seconds, since the relay coil may over-
heat and damaged.
Summary of Contents for RV125
Page 1: ...9 9 5 0 0 3 1 2 3 3 0 1 E...
Page 34: ...PERIODIC MAINTENANCE 2 21...
Page 191: ...ELECTRICAL SYSTEM 6 23 SPEEDOMETER Disassemble the speedometer as follows...
Page 241: ...8 10 RV125K4 K5 04 05 MODELS REAR FENDER INSTALLATION 6 5 N m 0 65 kgf m...
Page 251: ...Printed in Japan K3 K4 K5 K6...