ELECTRICAL SYSTEM 6-7
TROUBLESHOOTING
Battery runs down quickly.
Accessories
are installed
• Remove accessories.
No accessories
Current leaks
• Short circuit of wire harness
• Faulty electrical equipment
No current leaks
Measure the charging voltage
between the battery terminals.
(
:
6-8)
Correct
• Faulty battery
• Abnormal driving condition
Incorrect
Measure the continuity of the
generator coil.
(
:
6-9)
No continuity
• Faulty generator coil or
disconnected lead wires
Continuity
Check the battery for current
leaks. (
:
6-8)
Check accessories which use excessive
amounts of electricity.
Measure the generator no-load
voltage. (
:
6-9)
Incorrect
Correct
Inspect the regulator/rectifier.
(
:
6-10)
Incorrect
Correct
Inspect wirings.
Incorrect
Correct
Others
Battery overcharge
• Faulty regulator/rectifier
• Faulty battery
• Poor contact of generator lead wire coupler
• Faulty generator
• Faulty regulator/rectifier
• Short circuit of wire harness
• Poor contact of couplers
• Faulty battery
Summary of Contents for RV125
Page 1: ...9 9 5 0 0 3 1 2 3 3 0 1 E...
Page 34: ...PERIODIC MAINTENANCE 2 21...
Page 191: ...ELECTRICAL SYSTEM 6 23 SPEEDOMETER Disassemble the speedometer as follows...
Page 241: ...8 10 RV125K4 K5 04 05 MODELS REAR FENDER INSTALLATION 6 5 N m 0 65 kgf m...
Page 251: ...Printed in Japan K3 K4 K5 K6...