8-8 ELECTRICAL SYSTEM
Step4
1) Measure the continuity of the generator coil. (
!
8-10)
Is the resistance of generator coil OK?
Step5
1) Measure the generator no-load voltage. (
!
8-10)
Is generator no-load performance OK?
Step6
1) Inspect the regulator/rectifier. (
!
8-11)
Is the regulator/rectifier OK?
Step7
1) Inspect the wire harness.
Is the wire harness OK?
Battery overcharges
Faulty regulator/rectifier.
Faulty battery.
Poor contact of generator lead wire coupler.
YES
Go to Step5.
NO
• Faulty generator coil.
• Disconnected lead wires.
YES
Go to Step6.
NO
Faulty generator.
YES
Go to Step7.
NO
Faulty regulator/rectifier.
YES
Faulty battery
NO
• Short circuit of wire harness.
• Poor contact of coupler.
PartShark.com
877-999-5686
Summary of Contents for 2005 DL650K5
Page 22: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 51: ...PERIODIC MAINTENANCE 2 29 P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 54: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 249: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 275: ...COOLING AND LUBRICATION SYSTEM 6 25 REAR CYLINDER P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 460: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...
Page 472: ...P a r t S h a r k c o m 8 7 7 9 9 9 5 6 8 6...