Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 108
Wind speed Setup
Value
M1 Active
On
Label
SDI0P1
Meas Type
SDI-12
SDI-12 Address
0
SDI-12 Command
M!
SDI-12 Param
1
Meas Interval
00:15:00
Meas Time
00:00:00
Averaging Time
00:00:00
M2 Active
On
Label
SDI0P2
Meas Type
SDI-12
SDI-12 Address
0
SDI-12 Command
M!
SDI-12 Param
2
Meas Interval
00:15:00
Meas Time
00:00:00
Averaging Time
00:00:00
M3 Active
On
Label
SDI0P3
Meas Type
SDI-12
SDI-12 Address
0
SDI-12 Command
M!
SDI-12 Param
3
Meas Interval
00:15:00
Meas Time
00:00:00
Averaging Time
00:00:00
8.8.
ISCO Sampler triggering based on Stage
This section describes how to connect the sensor and how to set up X-Link to
trigger an ISCO sampler based on a user set level. In this example, the sensor is
an SDI-12 water level device.
The SDI-12 sensors use three wires for connection: one for data, one for power +
and one for power -. To wire it up, connect as follows:
SDI-12 Sensor
X-Link input
Data
Terminal Block 3
Power +
Terminal Block 4
Power -
Terminal Block 5
The ISCO sampler uses two wires for connection: one for trigger and one for
ground. To wire it up, connect as follows:
ISCO Sample
X-Link input
Trigger
Terminal Block 11
Ground
Terminal Block 9