The command SETUP NONDEFAULTS only shows the fields that have been
changed from defaults.
An easy way of setting up your station is to type WIZARD or just W. A setup
wizard will guide you through the most commonly used settings of the station
and of each measurement. The setup wizard may be used to configure one
specific measurement: typing M1 WIZARD or M1 W will set up measurement
one.
Every setup field can be changed by typing
setup = value
where setup is the
name of the field and value is the new value. By just typing the name of the field,
the current value and the range of the field are shown.
For example, typing STATION NAME shows the current station name. Typing
STATION NAME = SUTRON changes the station name.
>STATION NAME
Setup NOT changed
Station Name = DEMO, max length 23
To change setup try STATION NAME = SUTRON.
>STATION NAME = SUTRON DEV 1
Setup changed
Station Name = SUTRON DEV 1, max length 23
Changing measurement setup fields requires that the measurement be named.
For example, to change the
Measurement Type
it is not enough to type MEAS
TYPE. You need to provide the number of the measurement in question: M1
MEAS TYPE shows the
Measurement Type
of the first measurement. M2 MEAS
TYPE works for the second measurement.
>M1 MEAS TYPE
Setup NOT changed
Meas Type = SDI-12, Range (0=Precip Accumulation,
1=Precip Rate, 2=SDI-12, 3=Analog, 4=Battery, 5=Wind,
6=Digital, 7=Meta, 8=Manual Entry, 9=Internal Temp,
10=Accubar Pressure, 11=Accubar Temp)
To change setup try Station Name = Sutron
In the example above, the user typed M1 MEAS TYPE, which will show the
measurement type field of the first measurement. The example shows the type
as being
Internal Temp.
After the current type is shown, the range shows all the
options for the measurement type. To set up the measurement as SDI-12, the
user may type either M1 MEAS TYPE = SDI-12 or M1 MEAS TYPE = 2.