Sutron Corporation X-Link Operations & Maintenance Manual, Rev 1.63 5/24/2016 pg. 133
Slope = 0.709607
Offset = 13.297492
14.7.
Recording
By default, X-Link is not running. That means that it is neither making
measurements nor recording data.
To start X-Link, click the Start button in LinkComm, or type RECORDING = ON.
14.8.
Downloading the Log
X-Link will save the measured data in its flash memory each time a measurement
is made. This data is then available to download to via the RS232 port. The
command LOG command will start a Y-Modem transfer of the log to the
connected device.
It is possible to do a plain text download without Y-Modem by using the NY
option.
One can exclude the header with the NH option.
It is possible to download sensor data only omitting events with the NE
option.
>LOG HELP
DOWNLOAD or LOG will transfer the log from the
unit
LOG ALL gets whole log, just LOG gets since
last download,
LOG X gets X last days (LOG 3 gets last 3 days
worth of data)
LOG timeStart gets data since provided date
LOG timeStart timeEnd gets data between
provided dates
time can be YYYY/MM/DD HH:MM:SS or YYYY/MM/DD
or HH:MM:SS
e.g. LOG 12:00:00 13:00:00
e.g. LOG 2006/01/20 12:00:00 2006/01/21
12:00:00
append M1 to include only data from measurement
one
e.g. LOG 3 M1 M2
append NH to omit log header, NE to omit events
NY to not use YModem