Service and Maintenance
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 66
8.3.1
Changing Load Conditions
Correct the overload conditions immediately and also make sure that there is even load
distribution on the work surface in order to avoid premature wear of the mechanical
components.
During the further operation note that the system remains balanced and that the mounted
lifting elements have uniform contact with the ground.
IMPORTANT
One indicator of a uniform load distribution is that all the lifting elements in the
area of drive units (motor / cable outlet) have the same temperature.
8.3.2
Contamination
No sterile cleanliness is necessary, but regular cleaning will prolong the life of the system. Dust and
dirt can cause wear in moving components, such as shafts and bearings. Therefore, efforts should
be made to keep the components clean during the entire operating period.
8.3.3
Damages to Electrical Wires
Check the insulation of the electrical wires for visible signs of aging and wear. Replace defective or
damaged wiring.