Installation
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 53
6.4
Space Requirements
For detailed information on space requirements refer to the Section 4.1
“Technical specifications”.
6.5
Component Alignment
A level will be required to ensure the entire work surface is horizontal and level.
Place a spirit level on the surface of the work surface.
Ensure a very uniform load distribution when using several lifting elements.
Figure 43 Adjusting the work surface with a spirit level
By partially unscrewing the leveling feet from the foot base, adjust the individual leveling feet
such that the working surface is leveled and all attached lifting elements have uniform
contact with the ground. You can do this by unscrewing the leveling foot threaded bolt at the
hex. SW17 size nut (for this purpose, also see Figure 44).
Figure 44 Adjusting the work surface with a spirit level
Leveling feet with
threaded bolts and
SW17 size hex nut
SW17 size counter
nut