![Suspa ELS3-500S-BTU-Q-HeavyDuty Installation Instructions Manual Download Page 58](http://html1.mh-extra.com/html/suspa/els3-500s-btu-q-heavyduty/els3-500s-btu-q-heavyduty_installation-instructions-manual_1407727058.webp)
Operation
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 58
7.4.1.2
Programmable Manual Switch UBS/6-LCD (Optional)
Symbol
Function
Up:
Press the "Up" button until the work surface has reached the
desired height or the maximum height.
Down:
Press the “Down” button until the work surface has reached
the desired height or the minimum height.
+
Reset:
Press both direction keys simultaneously. The work surface
moves gradually to the lower mechanical end stop. The
controller acknowledges this reset drive with a signal tone.
Key “M”
Memory button for storing the memory positions. Optionally
you can also change the upper and lower lifting limits via the
setting mode.
Keys "1", "2" and "3"
Up to three memory positions can be stored. To reach the
memory position press and hold the respective key.
Table 19 Function of the programmable manual switch UBS/6-LCD
Storing the memory positions:
Move to the desired position and press the "M" key three times and then press the Key 1, 2 or 3.
The controller acknowledges the successful storage of the position with a signal tone. The memory
position is retained even after a power failure.
Repeat the procedure described to store new memory positions.