Design and Function
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 17
4
Design and Function
4.1
Technical Specifications
Technical Specifications
–
ELS3-500-HeavyDuty Height Adjustment System
Installation dimensions (Lifting element)
External profile / external tube dimensions:
70 x 70 mm
Internal tube dimensions:
65 x 65 mm
Motor housing dimensions:
202 mm x 120 mm x 56 mm
Stroke (L stroke):
500 mm
Retracted length Lin:
680 mm
Extended length Lout:
1180 mm
Fastening structure:
12 x M6
Fasting on foot stabilizer:
4 x M8
Controller
Input voltage:
230 V / 50 Hz (2,7 A)
Output rating:
28 VDC 340 VA at 10% ED
(1 min one at 25° C)
Standby use:
< 4 W (Standard); <0,4 W (Optional)
Protection class II:
Protective insulation
Performance data
Operating speed:
approx. 20 mm/s
Max. lifting capacity and holding load per
lifting element:
100 kg
Max. lifting capacity and holding load with
4-leg system:
400 kg
Duty cycle:
10% (Traversing time 2 min; Break time 18 min)
Protection type
Lifting elements:
IP 20 in accordance with DIN EN 60529
Controller:
IP 40 in accordance with DIN EN 60529
Manual switch:
IP 40 in accordance with DIN EN 60529
Traversing cycles
At least 10,000 cycles in compliance with maintenance
Table 9 Technical Specifications