Operation
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 62
Manual switch with status LED
and / or display
Manual switch without status LED
and / or display
1. The controller is
not working;
General Testing
If nothing is output on the display
and / or the status LED does not
light up when pressing a button,
check:
▪
whether the power cable is
plugged in properly into the
controller
▪
whether the power cable is
plugged in properly into the
socket
▪
whether the socket is
supplying power or is
switched on
▪
Replace the manual switch in
order to ensure that the
manual switch is not defective
▪
Notify your service partner if
the controller is still not
working.
Check:
▪
whether the power cable is
plugged in properly into the
controller
▪
whether the power cable is
plugged in properly into the
socket
▪
whether the socket is
supplying power or is
switched on
▪
Replace the manual switch in
order to ensure that the
manual switch is not defective
▪
If the error persists, continue
with step 2.
2. The controller is
not working, but
no acoustic signal
is heard (beep
tone)
▪
Initialize the controller.
▪
Notify your service partner if the controller is still not working.
2. The controller is
not working, but
no acoustic signal
is heard (beep
tone)
If the table has been moved previously for more than 2 minutes:
▪
Wait for 18 minutes and try again (switch-on period exceeded)
If the table has not been moved previously:
▪
Initialize the controller.
▪
Notify your service partner if the controller is still not working.
4. The table moves
briefly and then
comes to a
standstill
▪
Initialize the controller.
▪
Notify your service partner if the controller is still not working.
5. The table is
moving at a slant
▪
Initialize the controller.
▪
Check the load on the table if the fault persists.
▪
Initialize the controller once more.
▪
Notify your service partner if the controller is still not working.
Table 21 Troubleshooting