![Sun Oracle Fire X4470 M2 Service Manual Download Page 94](http://html1.mh-extra.com/html/sun-oracle/fire-x4470-m2/fire-x4470-m2_service-manual_1393134094.webp)
5-10
Sun Server X2-4 Service Manual • April 2013
FIGURE 5-4
Removing the Fan Board
▼
Install the Fan Board
1. Unpack the replacement fan board unit and place it on an antistatic mat.
2. Remove the fan board cable and power cables from the faulty fan board unit
and plug them into the fan board on the replacement fan board unit.
3. Reinstall the fan board unit (
FIGURE 5-5
):
a. Insert the fan board unit into the chassis, moving it down and toward the
front.
b. Reposition the front memory riser guide, routing the fan board and power
cable through the riser guide.
c. Plug the fan board cable and power cable into the connectors on the
motherboard.