Chapter 4
Servicing CRU Components That Require Server Power Off
4-9
b. Power off the server.
See
Section 2.6 “Powering Off the Server” on page 2-6
.
c. Extend the server to the maintenance position.
See
Section 2.4 “Positioning the Server for Maintenance” on page 2-4
.
d. Remove the top cover.
See
Section 2.7 “Removing the Server Top Cover” on page 2-8
.
2. Locate the memory riser containing the DIMM filler panel you want to remove.
3. Lift the memory riser straight up to remove it from the memory module socket.
4. Locate the DIMM filler panel you want to remove.
5. To remove the DIMM filler panel, do the following:
a. Rotate both DIMM slot ejectors outward as far as they will go.
The filler panel is partially ejected from the socket.
b. Carefully lift the DIMM filler panel straight up to remove it from the socket
(
FIGURE 4-6
).
Caution –
Whenever you remove a DIMM filler panel, replace it with another filler
panel or a DIMM; otherwise, the server might overheat due to improper airflow.
▼
Remove a Memory Riser and DIMM
1. Prepare for servicing:
a. Attach an antistatic wrist strap.
See
Section 2.3 “Performing Electrostatic Discharge and Static Prevention
Measures” on page 2-3
.
b. Power off the server.
See
Section 2.6 “Powering Off the Server” on page 2-6
.
c. Extend the server to the maintenance position.
See
Section 2.4 “Positioning the Server for Maintenance” on page 2-4
.
d. Remove the top cover.
See
Section 2.7 “Removing the Server Top Cover” on page 2-8
.
2. Identify the memory riser with the faulty DIMM by pressing the Fault Remind
button on the air divider (
FIGURE 4-3
).
Summary of Contents for Fire X4470 M2
Page 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Page 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Page 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Page 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Page 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Page 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Page 153: ...Appendix A Server Specifications A 3...
Page 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Page 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Page 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Page 182: ...C 6 Sun Server X2 4 Service Manual April 2013...