Chapter 6
Returning the Server to Operation
6-3
FIGURE 6-2
Inserting Server Back Into Rack
2. While pushing on the release tabs, slowly push the server into the rack.
Ensure that the cables do not get in the way.
3. Reconnect the cables to the back of the server.
If the cable management arm (CMA) is in the way, disconnect the left CMA release
and swing the CMA open.
4. Reconnect the CMA.
Swing the CMA closed and latch it to the left rack rail.
6.3
Powering On the Server
If you removed power from the server during maintenance, use the following
procedure to reapply main power for all server components.
▼
Power On the Server
Refer to
FIGURE 6-3
when completing the following procedure.