Chapter 7
Servicing the Server at Boot Time
7-5
TABLE 7-2
BIOS POST F1 and F2 Error Messages
BIOS POST Error Message
Error Type
Resolution
Uncorrectable Error Detected on Last Boot:IOH(n)
Protocol Error (Please Check SP Log for more
Details)
IOH error
• Press F1 to continue.
• Check the SP event log in Oracle ILOM
for more details.
Uncorrectable Error Detected on Last Boot:IOH(n)
QPI [
x
] Error (Please Check SP Log for more
Details)
IOH error
• Press F1 to continue.
• Check the fault management function and
the SP event log in Oracle ILOM for more
details.
Note -
Where QPI [
x
] equals 0 for QPI Link
0 or 1 for QPI Link 1.
Uncorrectable Error Detected on Last Boot:IOH(n)
PCI-E [
x
] Error (Please Check SP Log for more
Details)
IOH error
• Press F1 to continue.
• Check the fault management function and
the SP event log in Oracle ILOM for more
details.
Note -
Where PCI-E [
x
] port number can
range from 0 to 10 depending on the PCI
root port on IOH.
Uncorrectable Error Detected on Last Boot:IOH(n)
ESI Error (Please Check SP Log for more Details)
IOH error
• Press F1 to continue.
• Check the fault management function and
the SP event log in Oracle ILOM for more
details.
Uncorrectable Error Detected on Last Boot:IOH(n)
Thermal Error (Please Check SP Log for more
Details)
IOH error
• Press F1 to continue.
• Check the fault management function and
the SP event log in Oracle ILOM for more
details.
Uncorrectable Error Detected on Last Boot:IOH(n)
Miscellaneous Error (Please Check SP Log for more
Details)
IOH error
• Press F1 to continue.
• Check the fault management function and
the SP event log in Oracle ILOM for more
details.
Uncorrectable Error Detected on Last Boot:IOH(n)
VTd Error (Please Check SP Log for more Details)
IOH error
• Press F1 to continue.
• Check the SP event log in Oracle ILOM
for more details.
BMC Not Responding
ILOM error • Press F1 to continue.
Note -
This error message might display if
during the SP/BIOS communication an
internal error occurs. This error might
require you to restart the SP.
Summary of Contents for Fire X4470 M2
Page 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Page 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Page 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Page 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Page 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Page 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Page 153: ...Appendix A Server Specifications A 3...
Page 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Page 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Page 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Page 182: ...C 6 Sun Server X2 4 Service Manual April 2013...