3-10
Sun Server X2-4 Service Manual • April 2013
FIGURE 3-6
Installing a Fan Module
3. Apply firm pressure to the “Press here to latch” artwork on the top of the fan
module to ensure that the fan module is fully seated.
4. Verify that the Service Action Required LED on the replaced fan module is not
lit.
5. Verify that the Top Fan LED and the Service Action Required LED on the front
of the server are not lit.
See
Section 1.2 “Server Front Panel Features” on page 1-9
and
Section 1.3 “Server
Back Panel Features” on page 1-10
for locations of system LEDs.
Note –
If you are replacing a fan module when the server is powered down, the
LEDs might stay lit until power is restored to the server and the server can determine
that the fan module is functioning properly.
6. Return the server to the normal rack position.
See
Section 6.2 “Returning the Server to the Normal Rack Position” on page 6-2
.
Summary of Contents for Fire X4470 M2
Page 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Page 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Page 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Page 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Page 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Page 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Page 153: ...Appendix A Server Specifications A 3...
Page 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Page 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Page 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Page 182: ...C 6 Sun Server X2 4 Service Manual April 2013...