5-8
Sun Server X2-4 Service Manual • April 2013
▼
Install a Heatsink Filler Panel
1. Orient the heatsink filler panel so that the two captive screws line up with the
mounting studs.
2. Carefully position the heatsink filler panel on top of the CPU socket.
3. Tighten the two captive screws to secure the heatsink filler panel.
4. Return the server to operation:
a. Install the top cover.
See
Section 6.1 “Replacing the Server Top Cover” on page 6-1
.
b. Return the server to the normal rack position.
See
Section 6.2 “Returning the Server to the Normal Rack Position” on page 6-2
.
c. Power on the server.
See
Section 6.3 “Powering On the Server” on page 6-3
.
5.2
Servicing the Fan Board (FRU)
Use the following procedures to remove and install the fan board.
Caution –
These procedures require that you handle components that are sensitive
to static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
Section 2.3 “Performing
Electrostatic Discharge and Static Prevention Measures” on page 2-3
.
▼
Remove the Fan Board
1. Prepare for servicing:
a. Attach an antistatic wrist strap.
See
Section 2.3 “Performing Electrostatic Discharge and Static Prevention
Measures” on page 2-3
.
b. Power off the server completely and disconnect all power cords from the
server power supplies.
See
Section 2.6 “Powering Off the Server” on page 2-6
.
Summary of Contents for Fire X4470 M2
Page 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Page 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Page 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Page 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Page 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Page 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Page 153: ...Appendix A Server Specifications A 3...
Page 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Page 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Page 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Page 182: ...C 6 Sun Server X2 4 Service Manual April 2013...