7-2
Sun Server X2-4 Service Manual • April 2013
7.2
About the BIOS
The Basic Input/Output System (BIOS) has a setup utility stored in the BIOS flash
memory. The setup utility reports system information and you can use it to configure
the BIOS settings. The configurable data is provided with context-sensitive help and
is stored in the system's battery-backed CMOS RAM. If the configuration stored in
the CMOS RAM is invalid, the BIOS settings return to their default optimal values.
There are eight menus in the BIOS Setup Utility, which appear in this order: Main,
Advanced, PCIPnP, Boot, Security, RC settings, Chipset, and Exit. To navigate the
menus or options listed on the menu, use the keyboard arrow keys. The options or
fields that you can configure on a menu appear in color. For further instructions on
how to navigate and change settings in the BIOS Setup Utility, refer to the online
instructions provided on the menu.
The remaining sections in this chapter provide additional information about the BIOS
operations and menu options available on the server.
7.3
Default BIOS Power-On Self-Test (POST)
Events
At system startup, the BIOS performs a power-on self-test that checks the hardware
on the server to ensure that all components are present and functioning properly.
TABLE 7-1
identifies the events that can occur during BIOS POST, as well as specifies
whether these events can prevent the host from powering-on.
TABLE 7-1
BIOS POST Events
Event
Cause
Boot Continues
on Host?
User password violation
Attempt to enter password fails three times
No
Setup password violation
Attempt to enter password fails three times
No
Correctable ECC
Correctable ECC (error correction code) error detected
Does not
apply
Uncorrectable ECC
Uncorrectable ECC error detected
Does not
apply
No system memory
No physical memory detected in the system
No
Summary of Contents for Fire X4470 M2
Page 1: ...Sun Server X2 4 formerly Sun Fire X4470 M2 Service Manual Part No E20784 06 April 2013...
Page 14: ...xiv Sun Server X2 4 Service Manual April 2013...
Page 38: ...2 12 Sun Server X2 4 Service Manual April 2013...
Page 54: ...3 16 Sun Server X2 4 Service Manual April 2013...
Page 84: ...4 30 Sun Server X2 4 Service Manual April 2013...
Page 106: ...5 22 Sun Server X2 4 Service Manual April 2013 FIGURE 5 11 Installing the Motherboard...
Page 153: ...Appendix A Server Specifications A 3...
Page 154: ...A 4 Sun Server X2 4 Service Manual April 2013...
Page 167: ...Appendix B BIOS Setup Utility Menus B 13 FIGURE B 16 BIOS PCIPnP Menu Second Screen...
Page 176: ...B 22 Sun Server X2 4 Service Manual April 2013...
Page 182: ...C 6 Sun Server X2 4 Service Manual April 2013...