Chapter 4
Firmware and Blade Server Management
4-7
4.3.3.1
probe-scsi
and
probe-scsi-all
Commands
The
probe-scsi
and
probe-scsi-all
commands diagnose problems with the
SCSI devices.
Caution –
If you used the
halt
command or the Stop-A key sequence to reach the
ok
prompt, issuing the
probe-scsi
or
probe-scsi-all
command can hang the
system.
The
probe-scsi
command communicates with all SCSI devices connected to
on-board SCSI controllers. The
probe-scsi-all
command also accesses devices
connected to any host adapters installed in PCI slots.
For any SCSI device that is connected and active, the
probe-scsi
and
probe-scsi-all
commands display its loop ID, host adapter, logical unit number,
unique worldwide name (WWN), and a device description that includes type and
manufacturer.
The following sample output is from the
probe-scsi-all
command with a Netra
CP32x0 ARTM connected to the Netra CP3260 blade server.
CODE EXAMPLE 4-1
probe-scsi-all
Command Output
{0} ok
probe-scsi-all
This command may hang the system if a Stop-A or halt command
has been executed. Please type reset-all to reset the system
before executing this command.
Do you wish to continue? (y/n)
y
/pci@0/pci@0/pci@a/pci@0/usb@4,2/storage@2
Unit 0 Disk TUSB6250USB20 DISK DRIVE
/pci@0/pci@0/pci@8/scsi@0
MPT Version 1.05, Firmware Version 1.22.01.00
Target 2
Unit 0 Disk SEAGATE ST914602SSUN146G0400 286739329 Blocks, 146 GB
SASAddress 5000c5000576b0e5 PhyNum 7
Target 3
Unit 0 Disk SEAGATE ST914602SSUN146G0400 286739329 Blocks, 146 GB
SASAddress 5000c50005d16415 PhyNum 6
{0} ok
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...