Chapter 2
Hardware Installation
2-13
4. Press the top edge of the FB-DIMM toward the blade server until the retainer
clips click into place (see
➋
in
FIGURE 2-3
).
The small retainer clips on each side of the FB-DIMM slot click into place in the
notches on the sides of the FB-DIMM.
2.5.2
Adding or Replacing Compact Flash Card
You can install an optional Sun Compact Flash card on the Netra CP3260 blade
server. The Compact Flash card is not hot-swappable and there is no access to the
card once the blade server is installed in an ATCA chassis.
To install the Compact Flash card, use the arrow on the card’s label as a guide and
insert the card into the Compact Flash connector (
FIGURE 2-4
).
Note –
On the Netra CP3260, the Compact Flash is an USB removable media device.
Therefore, you must use the Solaris
rmformat
utility to format the device. Refer to
the
rmformat
(1) man page for more information.
Note –
Sun Compact Flash cards have a life of 2,000,000 write/erase cycles. Users
are responsible for ensuring that the operating system and applications do not
exceed this limitation.
If the Solaris OS is installed on the Compact Flash card, Sun recommends that you
reconfigure the swap space to another storage device.
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...