Chapter 2
Hardware Installation
2-23
Note –
Shielded cables are required for serial I/O ports. Unshielded cables can be
used on Ethernet ports to satisfy EMI compliance standards. The shields for all
shielded cables must be terminated on both ends.
Information on connecting each of these cables follows:
■
For Ethernet connections
, category 5e or better network cable is required. One
end of the Ethernet cable is connected to a suitable 10/100/1000BASE-T switch
and the other end to one of the Ethernet ports on the Netra CP3260 blade server.
A single 10/100BASE-T Ethernet port is also available on a Netra CP32x0 ARTM
when installed. Refer to the appropriate Netra CP32x0 ARTM User’s Guide for
more information.
Use the Ethernet device names shown in
TABLE 2-1
when configuring the Ethernet
ports.
■
A shielded asynchronous serial I/O cable
can be attached from serial
communication devices to the RJ-45 serial port on the Netra CP3260 blade
server’s front panel.
A serial port is also provided on the Netra CP32x0 ARTM. You can use either the
serial port on the Netra CP3260 blade server or the serial port on Netra CP32x0
ARTM, but only one of the ports should be used at one time.
Once a serial cable is connected, use the tip utility on the host to establish a
full-duplex terminal connection with the Netra CP3260 blade server.
At the UNIX prompt in a command tool or shell tool, type:
■
USB 2.0 cables
can be attached from USB devices to the dual USB 2.0-compliant
ports on the Netra CP3260 blade server’s front panel.
TABLE 2-1
Ethernet Device Names
Ethernet Ports
Solaris 10 OS
Device Name
Ethernet management port (on front panel)
e1000g4
#
tip -9600 /dev/ttya
(for serial port)
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...