5-14
Netra CP3260 Blade Server User’s Guide • April 2009
■
Environmental monitoring
■
Access to all environmental I
2
C devices
■
Access to all I
2
C devices when MPC is reset
5.2.8.1
Intelligent Platform Management Bus
The BMR-H8S provides dual buffered Intelligent Platform Management Bus (IPMB)
interfaces to the IPMB-0 bus on the PICMG 3.0 midplane. The I
2
C channels on the
H8S are connected the IPMB-A and IPMB-B through the I
2
C buffers. The I
2
C buffers
allow the blade server I
2
C to be isolated from the midplane until the blade server is
fully seated and the I
2
C bus on the midplane is idle.
5.2.8.2
Interface to the PPC
The BMR-H8S provides one serial payload interface to the PPC. This interface
supports hardware flow control,
RTS
(Request To Send) and
CTS
(Clear To Send).
5.2.8.3
IPMB-L Interface
The H8S provides a local IPMI interface wired to the ARTM’s MMC (
IPMB-L
). The
MMC IPMI interface is isolated through FET and controlled by H8 GPIO pins.
5.2.8.4
ATCA Hot-Swap Latch
Hot-swap is supported by monitoring of the hot-swap handle switch. The handle
switch goes directly to one of the GPIO pins on the H8S (PE5).
Payload Shutdown in Response to Hot-Swap
The hardware supports both non-graceful shutdown and graceful shutdown of
payload in response to a hot-swap event. In case of non-graceful shutdown,
firmware on the IPMC disables the voltage rails before turning the blue LED on.
Optionally the IPMC can send a message across the serial payload interface to the
PPC.
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...