Appendix B
Sun OEM IPMI Commands
B-3
Example (Terminal Mode):
[B8 00 80 00 00 2A] <-------
Request
[BC 00 80 00 00 00 2A 02 02 00 00 00 00] <----Response
■
The IPMC version is read as:
lower nibble of REV1 . high nibble of REV2 . low nibble of REV2
In the preceding example, the IPMC version is
2.0.0.
■
The CPLD version is read as:
-> lower nibble of CPLD version byte
In the example, the CPLD version is
2.
B.2
Get RTM Status
Command
You can use the
Get RTM Status
command to detect the presence of a rear
transition module (RTM) in the system.
Command
NetFn
Opcode
Reference
Get
_
RTM
_
Status
0x2E (OEM)
0x88
CPLD Specification
TABLE B-2
Get RTM Status
Command Data Bytes
Type
Byte
Data Field
Request data
Byte1
00
Byte2
00
Byte3
2A
Response data
Byte1
Completion code:
00 = OK
C1 = Command not supported
CC = Invalid data in request
Byte2
00
Byte3
00
Byte4
2A
Byte5
RTM presence
Bits 7 to 1 = 0
Bits 0
= RTM presence (0 = RTM not detected,
1 = RTM detected)
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...