Chapter 2
Hardware Installation
2-5
2.5
Configuring On-Board Hardware
This section provides the procedures for adding or replacing the on-board hardware
components such as memory modules, a Compact Flash card, and the time-of day
(TOD) battery. Read and perform the procedures, as necessary,
before
installing the
Netra CP3260 blade server into the chassis.
2.5.1
Adding or Replacing FB-DIMM Memory Modules
The Netra CP3260 blade server supports a total of 8 FB-DIMMs and a maximum
memory capacity of 16 Gbytes (using eight 2-Gbyte DIMMs).
FIGURE 2-1
shows the
location of the FB-DIMMs. The Netra CP3260 blade server accommodates the
following:
■
Eight standard FB-DIMMs, buffered, and registered
■
1-Gbyte or 2-Gbyte FB-DIMM modules
Note –
You cannot mix 1-Gbyte and 2-Gbyte FB-DIMMs. All eight DIMMs must be
the same density (that is, all 1-Gbyte or all 2- Gbyte FB-DIMMs).
The Netra CP3260 blade server supports FB-DIMM memory modules that have the
following characteristics:
■
Each DIMM has a 72-bit-wide data bus (64+8 ECC) and up to 14 address bits.
■
Memory controller supports 128-bit data plus 9-bit error-correcting code (ECC).
■
Maximum of 16 Gbytes (eight 2-Gbyte FB-DIMMs) or 8 Gbyte (eight 1-Gbyte
FB-DIMMs).
■
FB-DIMM @1.55 volts or [email protected] volts
For information about sensors, refer to the
Netra CT 900 Software Developer’s Guide
(819-1175)
.
For additional information, see
Section 5.2.2, “Memory Subsystem” on page 5-9
.
FIGURE 2-1
shows the location of the DIMMs.
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...