4-4
Netra CP3260 Blade Server User’s Guide • April 2009
4.2.2
POST Diagnostic and Error Message Format
POST diagnostic and error messages are displayed on a console. The format of the
these messages is the following:
The following is an example of a POST error message
4.3
OpenBoot Firmware
The Solaris OS installed operates at different run levels. For a full description of run
levels, refer to the Solaris system administration documentation.
Most of the time, the OS operates at run level 2 or run level 3, which are multiuser
states with access to full system and network resources. Occasionally, you might
operate the system at run level 1, which is a single-user administrative state.
However, the lowest operational state is run level 0.
When the OS is at run level 0, the
ok
prompt appears. This prompt indicates that the
OpenBoot firmware is in control of the system.
There are a number of scenarios under which OpenBoot firmware control can occur.
By default, before the operating system is installed, the system comes up under
OpenBoot firmware control.
■
When the auto-boot? OpenBoot configuration variable is set to false, the system
boots to the
ok
prompt.
■
When the operating system is halted, the system transitions to run level 0 in an
orderly way.
Core-ID
:
Strand-ID
ERROR: TEST =
test-name
Core-ID
:
Strand-ID
H/W under test =
description
Core-ID
:
Strand-ID
Repair Instruction
Core-ID
:
Strand-ID
MSG =
error-message-body
Core-ID
:
Strand-ID
END_ERROR
3:2>ERROR: TEST = L2-Cache Functional
3:2>H/W under test = Core l2 Cache
3:2>Repair Instructions: Replace items in order listed by ’H/W
under test’ above.
3:2>MSG = No way found to match tag address 00000000.00600000,
state 3
3:2>END_ERROR
Summary of Contents for Sun Netra CP3260
Page 18: ...xviii Sun Netra CP3260 Blade Server User s Guide April 2009...
Page 23: ...Chapter 1 Introduction 1 5 FIGURE 1 2 Netra CP3260 Blade Server Top View...
Page 24: ...1 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 27: ...Chapter 1 Introduction 1 9 FIGURE 1 3 Netra CP3260 Blade Server in an ATCA Shelf Enclosure...
Page 36: ...1 18 Netra CP3260 Blade Server User s Guide April 2009...
Page 42: ...2 6 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 1 FB DIMM Memory Locations...
Page 43: ...Chapter 2 Hardware Installation 2 7...
Page 44: ...2 8 Netra CP3260 Blade Server User s Guide April 2009...
Page 52: ...2 16 Netra CP3260 Blade Server User s Guide April 2009 FIGURE 2 5 TOD Battery Location...
Page 53: ...Chapter 2 Hardware Installation 2 17...
Page 61: ...Chapter 2 Hardware Installation 2 25 FIGURE 2 9 Hot Swap Latch and Hot Swap LED...
Page 62: ...2 26 Netra CP3260 Blade Server User s Guide April 2009...
Page 106: ...5 6 Netra CP3260 Blade Server User s Guide April 2009...
Page 140: ...B 8 Netra CP3260 Blade Server User s Guide April 2009...