Firmware Upgrades
Sun Confidential: Internal Only
62
Sun Fire 3800 - 6800 Quick Reference Guide
SunService Sun Microsystems, Inc. All Rights Reserved. Enterprise Services
sc0-4800c:SC> showb -v -p version
Component Segment Compatible In Date Time Build Version
--------- ------- ---------- -- ---- ---- ----- -------
SSC0/FP0 - - - - - - RTOS version: 41
SSC0/FP1 ScApp Reference 12 09/20/2004 21:32 14.1 5.18.0
SSC0/FP1 Ver - - 09/20/2004 21:31 14.1 5.18.0 Build_14
IB6/FP0 iPOST Yes 12 09/20/2004 21:24 14.1 5.18.0
IB6/FP0 Ver - - 09/20/2004 21:28 14.1 5.18.0 Build_14
/N0/SB0/FP0 POST Yes 12 09/20/2004 21:22 14.1 5.18.0
/N0/SB0/FP0 OBP Yes 12 09/20/2004 21:21 14.1 5.18.0
/N0/SB0/FP0 Ver - - 09/20/2004 21:26 14.1 5.18.0 Build_14
/N0/SB0/FP1 POST Yes 12 09/20/2004 21:22 14.1 5.18.0
/N0/SB0/FP1 OBP Yes 12 09/20/2004 21:21 14.1 5.18.0
/N0/SB0/FP1 Ver - - 09/20/2004 21:26 14.1 5.18.0 Build_14
sc0-4800c:SC>
SC1 will not have the
showboards
ScApp in a dual-SC configuration. To
display the status of the system controller use the
showsc
command
which shows system controller uptime, version, and configuration.
sc1-4800c:SC> showsc -v
SC: SSC1
Main System Controller
SC Failover: disabled
Clock failover enabled.
SC date: Thu Apr 07 10:53:09 BST 2005
Europe/London GMT+00:00 Greenwich Mean Time
SC uptime: 16 days 15 hours 53 minutes 20 seconds
ScApp version: 5.18.0 Build_14
Version build: 14.1
Version String: 5.18.0
RTOS version: 41
SC POST diag level: off
Clock source is: 75MHz
sc1-4800c:SC>