3-24
Sun Blade X6450 Server Module Service Manual • May 2009
3.4.3
Replacing DIMMs (CRU)
This section describes how to replace DIMMs. It provides the rules for populating
DIMM slots.
Before You Begin
■
For troubleshooting information, see
Section 3.3, “Troubleshooting Server Issues”
on page 3-17
.
3.4.3.1
DIMM Population Rules
The DIMM population rules for the server module are listed here:
■
The server module can support a maximum of 24 DIMMs.
■
DIMM slots are paired.
■
DIMMs must be installed in pairs.
■
The slots for the first two pairs are blue; all others are black. For example, pairs A0
and B0 are blue, and pairs C0 and D0 are blue.
■
The two DIMMs within each pair must be identical (same manufacturer, size, and
speed).
TABLE 3-8
shows the population rules based on the number of DIMMs.
FIGURE 3-9
shows the DIMM numbering and positions
TABLE 3-8
DIMM Slots and Locations
Number
of DIMMs
Slot
Location
Number
of DIMMs
Slot
Location
2
A0, B0
14
All of the above, plus: A3, B3
4
All of the above, plus: C0, D0
16
All of the above, plus: C3, D3
6
All of the above, plus: A1, B1
18
All of the above, plus: A4, B4
8
All of the above, plus: C1, D1
20
All of the above, plus: C4, D4
10
All of the above, plus: A2, B2
22
All of the above, plus: A5, B5
12
All of the above, plus: C2, D2
24
All of the above, plus: C5, D5
Summary of Contents for Blade X6450
Page 12: ...xii Sun Blade X6450 Server Module Service Manual May 2009...
Page 14: ...xiv Sun Blade X6450 Server Module Service Manual May 2009...
Page 74: ...2 44 Sun Blade X6450 Server Module Service Manual May 2009...
Page 126: ...3 52 Sun Blade X6450 Server Module Service Manual May 2009...
Page 148: ...A 2 Sun Blade X6450 Server Module Service Manual May 2009...
Page 162: ...Index 4 Sun Blade X6450 Server Module Service Manual May 2009...