Appendix B
BIOS Power-On Self-Test (POST) Codes
B-5
■
Warning
or
Not an Error
– The message appears on the screen. An error record is
logged to the system event log (SEL). The system continues booting with a
degraded state. The user might want to replace the unit.
■
Pause
– The message appears on the screen, an error is logged to the SEL, and user
input is required to continue. The user can take immediate corrective action or
choose to continue booting.
■
Halt
– The message appears on the screen, an error is logged to the SEL, and the
system cannot boot unless the error is resolved. The user needs to replace the
faulty part and restart the system.
TABLE B-1
Error Messages and Responses
Error Code
Error Message
Response
0000
Timer Error
Pause
0003
CMOS Battery Low
Pause
0004
CMOS Settings Wrong
Pause
0005
CMOS Checksum Bad
Pause
000B
CMOS memory size Wrong
Pause
000C
RAM R/W test failed
Pause
000E
A: Drive Error
Pause
000F
B: Drive Error
Pause
0012
CMOS Date/Time Not Set
Pause
0040
Refresh Timer Test Failed
Halt
0041
Display Memory Test Failed
Pause
0042
CMOS Display Type Wrong
Pause
0043
~<INS> Pressed
Pause
0044
DMA Controller Error
Halt
0045
DMA-1 Error
Halt
0046
DMA-2 Error
Halt
0047
Unknown BIOS error. Error code = 0047
Halt
0048
Password Check Failed
Halt
0049
Unknown BIOS error. Error code = 0049
Halt
004A
Unknown BIOS error. Error code = 004A
Pause
004B
Unknown BIOS error. Error code = 004B
Pause
004C
Keyboard/Interface Error
005D
S.M.A.R.T. Command Failed
Summary of Contents for Blade X6450
Page 12: ...xii Sun Blade X6450 Server Module Service Manual May 2009...
Page 14: ...xiv Sun Blade X6450 Server Module Service Manual May 2009...
Page 74: ...2 44 Sun Blade X6450 Server Module Service Manual May 2009...
Page 126: ...3 52 Sun Blade X6450 Server Module Service Manual May 2009...
Page 148: ...A 2 Sun Blade X6450 Server Module Service Manual May 2009...
Page 162: ...Index 4 Sun Blade X6450 Server Module Service Manual May 2009...