Chapter 3
Maintaining the Server
3-21
3.4.1
Replacing the System Battery (CRU)
The system battery is a customer replaceable unit (CRU). It is located on the
motherboard. If an optional RAID Expansion Module is installed, you must remove
the card to access the battery.
▼
To Replace the System Battery
1. Power off the server module, and remove the server module from the chassis
(see
“To Remove the Server Module From the Chassis” on page 3-13
).
Caution –
Possible chassis shutdown. Do not operate the system with empty slots.
Always insert a filler into an empty slot to reduce the possibility of module
shutdown.
2. Remove the main cover as described in
“To Remove the Main Cover” on
page 3-15
.
3. If a RAID expansion module (REM) card is present, remove the card (
see
“To
Remove a RAID Expansion Module” on page 3-38
)
.
The system battery is located on the motherboard (see
FIGURE 3-7
).
4. Remove the battery by gently pulling the clip away from the edge of the battery
and lifting the battery straight up. See
FIGURE 3-7
.