Chapter 3
Maintaining the Server
3-27
6. To install a DIMM:
a. Ensure that the DIMM slot ejectors at each end of the memory socket are
fully open (rotated outward).
b. Align the notch on the bottom edge of the DIMM with the key in the DIMM
slot. See the inset in
FIGURE 3-11
.
FIGURE 3-11
Installing a DIMM with Slot Alignment Key
c. Press down evenly on both top corners of the DIMM until the ejectors rotate
upward and snap into place. See
FIGURE 3-11
.
7. Install the server module main cover, and insert the server module into the
chassis.
8. Use the SP to verify and view DIMM component information. See the
corresponding ELOM or ILOM documentation collection.