Installing Your Cooker
Connecting the electricity supply
This appliance must be earthed!
l
This appliance must be fitted using a double pole unit of 30 ampere minimum
capacity with 3mm minimum contact at all poles.
l
Access to the mains terminal is gained by opening the terminal block cover at
the rear of the appliance - use a flat bladed screw driver for this.
l
Connection should be made with a 6.0mm
2
twin and earth cable.
l
First strip the wires. then push the cable through the cable clamping the
terminal block cover.
l
Connect the cable to the terminal
block and tighten the cable clamp
screw - see diagram.
l
Close the terminal box, ensuring that
the cover is engaged on the locking
tabs.
l
Sufficient cable should be used to allow the cooker to be pulled out, but must
hang clear of the floor so it does not become twisted or trapped when the
cooker is pushed back.
Please ensure that the user has this copy of the handbook, and the appliance is
in place. Thank you.
Equipment you will need:
Flat bladed screw driver
1
2
3
4
5
Cable
clamp
Earth
(Green / Yellow
or sleeving)
Live
(Red or Brown)
Neutral
(Black or Blue)
62
All appliances, excluding Gourmet 900DF
08 27189 01 Ra DF 2/6/05 9:40 AM Page 66
Summary of Contents for Gourmet Professional 1100DF
Page 70: ...Technical Data 66 ...
Page 71: ...Technical Data 67 Dual Circuit electric ...
Page 72: ...Technical Data 68 ...
Page 73: ...Technical Data 69 ...
Page 74: ...Technical Data 70 ...
Page 78: ......