Safety
2
Safety tests
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batte-
ries must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal voltage
U
Batt
Test values
50 VDC
24 volts
> 1200 Ω
100 VDC
48 volts
> 2400 Ω
Battery
100 VDC
Batt+
Batt-
Battery tray
80 volts
> 4000 Ω
.
Test values for the entire truck
Nominal voltage Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 volts
50 VDC
Min. 50 kΩ
> 24 kΩ
48 volts
100 VDC
Min. 100 kΩ
> 48 kΩ
80 volts
100 VDC
Min. 200 kΩ
> 80 kΩ
.
171533 EN - 02/2019 - 19
49
Summary of Contents for RX60-35/600
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...1 Foreword ...
Page 38: ...1 Foreword Environmental considerations 24 171533 EN 02 2019 19 ...
Page 39: ...2 Safety ...
Page 71: ...3 Overviews ...
Page 73: ...Overviews 3 General view 171533 EN 02 2019 19 59 ...
Page 86: ...3 Overviews Operating devices and display elements 72 171533 EN 02 2019 19 ...
Page 87: ...4 Operation ...
Page 384: ...4 Operation Decommissioning 370 171533 EN 02 2019 19 ...
Page 385: ...5 Maintenance ...
Page 392: ...5 Maintenance General maintenance information 378 171533 EN 02 2019 19 ...
Page 396: ...5 Maintenance General maintenance information 382 171533 EN 02 2019 19 ...
Page 432: ...5 Maintenance 1000 hour maintenance yearly maintenance 418 171533 EN 02 2019 19 ...
Page 433: ...6 Technical data ...
Page 458: ...6 Technical data Fuse assignment 444 171533 EN 02 2019 19 ...
Page 469: ......
Page 470: ...STILL GmbH 171533 EN 02 2019 19 ...