Operation
4
Display messages
SURVEILLANCE message
If the
SURVEILLANCE
message appears
in the display, there is a fault in the process
monitoring.
This shuts off the drive unit.
– Switch the key switch to the "0" position and
then back to the "I" position.
– Start the engine.
– Release accelerator pedal.
– Select the drive direction again.
NOTE
If this error occurs sporadically, it can be tole-
rated. If the operational capacity is impaired,
notify your authorised service centre.
NOT VALID message
If the message
NOT VALID
appears on the
display, an incorrect driver PIN has been
entered when entering the access code.
– Once the message goes out, enter the
driver PIN again.
Drive-specific messages
Message ! PARKING BRAKE OIL
PRESSURE
If the following message appears in the display
when the accelerator pedal is actuated:
! PARKING BRAKE OIL PRESSURE
, the
service brake of the truck is not yet ready for
use.
The driving speed is limited to 5 km/h.
When the service brake is ready for operation,
the message disappears. The speed limitation
is cancelled.
MOT/GEN.-TEMP. message
If the
MOT/GEN.-TEMP.
message appears,
the traction motor or the generator is over-
heated or a cable is broken.
171533 EN - 02/2019 - 19
291
Summary of Contents for RX60-35/600
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...1 Foreword ...
Page 38: ...1 Foreword Environmental considerations 24 171533 EN 02 2019 19 ...
Page 39: ...2 Safety ...
Page 71: ...3 Overviews ...
Page 73: ...Overviews 3 General view 171533 EN 02 2019 19 59 ...
Page 86: ...3 Overviews Operating devices and display elements 72 171533 EN 02 2019 19 ...
Page 87: ...4 Operation ...
Page 384: ...4 Operation Decommissioning 370 171533 EN 02 2019 19 ...
Page 385: ...5 Maintenance ...
Page 392: ...5 Maintenance General maintenance information 378 171533 EN 02 2019 19 ...
Page 396: ...5 Maintenance General maintenance information 382 171533 EN 02 2019 19 ...
Page 432: ...5 Maintenance 1000 hour maintenance yearly maintenance 418 171533 EN 02 2019 19 ...
Page 433: ...6 Technical data ...
Page 458: ...6 Technical data Fuse assignment 444 171533 EN 02 2019 19 ...
Page 469: ......
Page 470: ...STILL GmbH 171533 EN 02 2019 19 ...