Operation
4
Decommissioning
– To relieve the strain on the load chains,
lower the fork onto a suitable supporting
surface, e.g. a pallet.
– Check the hydraulic oil level. Top the oil up
if necessary.
– Apply a thin layer of oil or grease to all
uncoated moving parts.
– Lubricate the truck.
– Lubricate the joints and controls.
– Lubricate the slide elements and guides of
the hydraulic battery carrier (variant); see
the section entitled "Lubricating the slide
elements" in the chapter entitled "1000-hour
maintenance/annual maintenance".
– Lubricate the catch rail of the hydraulic
battery carrier (variant); see the section
entitled "Oiling the catch rails" in the chapter
entitled "1000-hour maintenance/annual
maintenance".
– Lubricate the battery interlock and the
battery cover; see the section entitled
"Checking the battery interlock and battery
cover" in the chapter entitled "Remaining
ready for operation".
CAUTION
Risk of component damage!
If you remove the battery male connector with the
key switch switched on (under load), an arc will be
produced. This can cause the contacts to erode,
which considerably shortens their service life.
– Switch off the key switch before disconnecting
the battery male connector.
– Do not disconnect the battery male connector
while the key switch is switched on, except in an
emergency.
– Disconnect the battery male connector.
– Check the battery condition, acid level and
acid density.
– Service the battery.
NOTE
Store only fully charged batteries.
171533 EN - 02/2019 - 19
367
Summary of Contents for RX60-35/600
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...1 Foreword ...
Page 38: ...1 Foreword Environmental considerations 24 171533 EN 02 2019 19 ...
Page 39: ...2 Safety ...
Page 71: ...3 Overviews ...
Page 73: ...Overviews 3 General view 171533 EN 02 2019 19 59 ...
Page 86: ...3 Overviews Operating devices and display elements 72 171533 EN 02 2019 19 ...
Page 87: ...4 Operation ...
Page 384: ...4 Operation Decommissioning 370 171533 EN 02 2019 19 ...
Page 385: ...5 Maintenance ...
Page 392: ...5 Maintenance General maintenance information 378 171533 EN 02 2019 19 ...
Page 396: ...5 Maintenance General maintenance information 382 171533 EN 02 2019 19 ...
Page 432: ...5 Maintenance 1000 hour maintenance yearly maintenance 418 171533 EN 02 2019 19 ...
Page 433: ...6 Technical data ...
Page 458: ...6 Technical data Fuse assignment 444 171533 EN 02 2019 19 ...
Page 469: ......
Page 470: ...STILL GmbH 171533 EN 02 2019 19 ...