The engine surg-
es, vibrates or runs
irregularly.
There is a malfunction in the fuel
system.
Carry out a check for leaks (visual
check).
Call Linde service engineer to check.
The engine's out-
put is poor (lack of
power).
The air filter is dirty or blocked.
Replace the air filter element.
The charge-air temperature is too
high; the exterior of the charge-air
cooler or engine radiator is dirty.
Clean the exterior of the charge-air cool-
er and engine radiator.
The coolant temperature is too
high.
Check the fan speed.
Please consult Linde Service engineer.
Malfunction in the fuel system
(blocked, leaking).
Visual inspection for leaks.
Please consult Linde Service engineer.
Poor fuel grade.
Use the specified type of fuel and fuel
grade
The charge-air system is leaking;
the hose clip on the charge-air
hose is loose or damaged.
Check the charge-air system for leaks.
Please consult Linde Service engineer.
An operating restriction is activa-
ted due to an emissions-relevant
malfunction.
Observe the notes on warning and indi-
cator lamps
There is an inter-
ruption in the trac-
tive power.
The cause must be established in
Linde service engineer.
Please consult Linde Service engineer.
The engine brak-
ing effect is poor.
The cause must be established in
Linde service engineer.
Please consult Linde Service engineer.
Fuel consumption
is too high.
See the operating notes in the
fuel consumption section
If the problems cannot be fixed, consult
Linde Service engineer.
The engine gets
too hot (according
to the coolant tem-
perature gauge).
There is not enough coolant in the
coolant circuit.
Add coolant and bleed the system.
The coolant temperature sensor
or display is faulty.
Please consult Linde Service engineer.
The poly-V-belt is damaged.
Please consult Linde Service engineer.
The fan does not switch on cor-
rectly.
Please consult Linde Service engineer.
The engine radiator is dirty on the
inside; the engine radiator is very
dirty on the outside.
Clean the engine radiator.
The thermostat is faulty.
Please consult Linde Service engineer.
Indicator lamps do
not light up at IG-
NITION ON.
The lamps are faulty or the electri-
cal cables are interrupted.
Please consult Linde Service engineer.
The charge cur-
rent indicator lamp
lights up when the
engine is running.
The poly-V-belt slipping.
check the belt tensioner function.
Check That the poly-V-belt contact sur-
faces are not torn, damaged, oily or
worn down.
Please consult Linde Service engineer.
The poly-V-belt is torn.
Please consult Linde Service engineer.
Maintenance
5
Troubleshooting
249
5001 801 1625 EN - 05/2022 - 03
Summary of Contents for 5410
Page 2: ......
Page 11: ...1 Introduction ...
Page 32: ...Introduction 1 Using working platforms 22 5001 801 1625 EN 05 2022 03 ...
Page 33: ...2 Safety ...
Page 45: ...Safety 2 Residual risks 35 5001 801 1625 EN 05 2022 03 ...
Page 58: ...Safety 2 Medical equipment 48 5001 801 1625 EN 05 2022 03 ...
Page 59: ...3 Overview ...
Page 64: ...Overview 3 Switch panel 54 5001 801 1625 EN 05 2022 03 ...
Page 65: ...4 Operation ...
Page 219: ...5 Maintenance ...
Page 266: ...Maintenance 5 Decommissioning the truck 256 5001 801 1625 EN 05 2022 03 ...
Page 267: ...6 Technical data ...
Page 268: ...Truck dimensions Technical data 6 Truck dimensions 258 5001 801 1625 EN 05 2022 03 ...
Page 282: ...Technical data 6 Overview of type sheets 1200 mm load centre 272 5001 801 1625 EN 05 2022 03 ...
Page 287: ......