Place a suitable collection tray beneath
drain hose(1).
–
Open drain plug(2)until the water/fuel mix-
ture flows out of drain hose(1)
–
Turn drain plug(2)closed.
–
Dispose of the collected water/fuel mixture
in an environmentally responsible manner,
e.g. at a qualified specialist workshop.
–
Check that drain plug(2)is closed. When the
engine is running and drain plug(2)is open,
fuel is lost through drain hose(1).
–
If the indicator lamp does not go out after
draining: drain the fuel filter again.
–
If the indicator lamp does not go out af-
ter draining for the second time: consult
Linde service engineer and have the cause
checked immediately.