– 95 –
MAINTENANCE GUIDE
§2. [LVPS Assembly
↔
Fuser Assembly]
Signal Wire Name
Reference
AC N
Neutral side of the AC input from the power supply
AC L
Line side of the AC input from the power supply
*1:
Temperature of the thermostat when the point of contact is open: contact temperature 125
°
C (Non-touch type)
*2:
Rated power of the heater rod
100V Model: 320
±
16W(115V), 220V Model: 320
±
16W(220V)
*3:
Resistance of the thermistor
Temperature (
°
C)
10
20
30
140
160
Resistance (K
Ω
)
428.5
270.4
174.7
4.129
3.178
FG
–
–
–
1
2
3
⊃
⊃
⊃
P/J114
–
–
–
1
2
3
⊃
⊃
⊃
P/J114
100V MODEL
220V MODEL
MAIN POWER
SWITCH
FG
AC L
AC N
LVPS ASSY
PL 5.2
FUSER ASSY
PL 3.1
HEATER ROD
THERMAL
FUSE
THERMOSTAT
HEAT ROLLER
1
2
–
–
⊃
⊃
3
–
⊃
P/J112