Clearances between the fire and all combustible materials must conform to
National Regulations.
•
This appliance is supplied as a complete fireplace package including gas fire
burner unit, enclosure and fascia. This fire must be installed and used in
accordance with these instructions.
•
The builders opening or fireplace opening must be constructed of a non-
combustible material.
•
For some countries a non-combustible hearth must be fitted in front of the
fire in accordance with National Regulations (e.g. United Kingdom).
•
Flue System:
The
FR920HE
can be used with a brick/precast chimney or
using a flue liner with a minimum diameter of 125mm (5”). If installing in a
chimney this should be inspected prior to installation to ensure it is working
correctly. If the chimney has previously been used with a solid fuel
appliance it will also require sweeping. Consult a flue specialist to inspect
and test the flue prior to installation. The chimney must have a minimum
effective height of at least 2 metres. This is not necessary if the flue has
previously been used with a gas appliance or if it is a new installation. (see
technical section for full details on the flue requirements). Any flue damper
plate or flue restrictor must be removed.
•
Gas Supply:
This appliance is intended for use on a gas installation with a
governed meter. The FR920HE is available for Natural Gas only. Inlet is via
an 8mm connection via the isolation valve provided with the fire. The gas
connections must be in accordance with National Regulations. If the gas line
is longer than 1.5mtrs then the gas line should be increased in diameter to
15mm and possibly larger depending on the final length to ensure a steady
gas supply. The fire is supplied with an isolation valve inside the appliance.
This must be used. When closed this will allow the complete burner and
control assembly to be disconnected for maintenance or repair in
accordance with National Regulations.
•
The pilot light and flame sensing device fitted to this fire is also an
atmosphere sensing device. If for any reason any part of the pilot assembly
is to be replaced ALL the assembly including the pilot burner, thermocouple,
electrode and injector must be exchanged complete for an original
manufacturer’s pilot assembly only. This atmosphere sensing device is not
adjustable and must not be put out of action. The pilot light shuts off both
the main burner and pilot if evacuation of the combustion products is
interrupted (blocked chimney).
If the flame supervision device operates
no attempt should be made to re-light the gas fire until at least 3
minutes have elapsed. To relight the fire consult page 52.
If the
device operates again do not use the fire until the reason for operation is
found – consult a Gas Safe Engineer.
•
The
FR920HE
is battery operated; therefore no mains electrical supply is
required. Power to the appliance is provided by 3 high power alkaline 1.5V
batteries (AA size) these batteries can be changed to Nickel Metal Hydride
rechargeable batteries providing they have a minimum capacity of 2200
mAh. A set of high power alkaline batteries (AA size) will last a minimum of
1 year. The life of the battery will depend on how the appliance is used and