Thank you for purchasing a Kent wood fire. Used correctly it will provide you 

with many years of warmth in your home. Kent wood fires have been the main 

source of heating for many Kiwi homes, with nearly 400,000 installed. 

 

Controlling the Tilefire: 

 

On initial light up, the presence of smoke may be noticed. This is normal and 

will dissipate quickly. DO NOT BURN YOUR HEATER TOO QUICKLY TO BEGIN WITH

Allow several small fires to build up a layer of ash in the heater, and cure the 

paint before using maximum power. 

 

The Tilefire requires up to 40 cu.m/h of fresh air for burning, and this must come 

from outside the house. A normal house will allow enough air in through 

incidental openings to satisfy this. We recommend that a source of air be 

located near the heater for best performance. This can be simply a window 

that is left ajar while the heater is in use. If this is not possible, and the house is 

particularly air-tight, a vent may need to be installed next to the heater to 

provide the air required. Lack of air will lead to a heater that is hard to light 

and get going, or in bad cases, to smoke spilling back into the room. This 

situation can also lead to excessive carbon monoxide levels through 

incomplete combustion. 

 

There is only one control on the Tilefire. This is the air control, on the right side of 

the ash spill tray below the door, which adjusts the amount of air that enters 

the heater. Pushing in the control knob reduces the amount of air entering the 

heater and reduces the burning rate. 

 

While an air control is fitted, it is recommended that, for the cleanest 

operation, this is left fully open and the amount of heat generated is adjusted 

by the amount of fuel that is used. The heater burns cleanest when it is running 

at a high rate. Reducing the air inlet setting drops the internal temperature of 

the fire, which can lead to excessive smoke and emissions being produced. 

 

This model is designed for easy lighting, simple operation and controllable 

heat outputs. 

 

 

 

Please ensure your installer completes and signs the 

warranty registration card in this booklet and you return it 

to us. We encourage you to read the warranty conditions 

and draw your attention to improper fuel use. 

Standard Warranty: 

 

Your Kent wood burner is warranted for 10 years on the firebox with the exception of 

the following Kent parts: glass, glass seal, door seal, fire bricks, flue, secondary air 

system and removable baffle which will all have a 12 month warranty (parts only) 

provided they have been installed by a NZ Home Heating Association registered 

installer.  The warranty does not apply to normal wear and tear, misuse or neglect, 

nor if parts of the heater are replaced with non genuine Kent parts. Kent 

recommends an annual service and flue sweep (years two to five) with replacement 

of parts if recommended to obtain maximum life out of your wood burner. 

 

Conditions: 

 

Your Kent wood burner must be installed in accordance with the manufacturer’s 

instructions and all applicable standards, regulations and by-laws. Your Kent wood 

burner must be installed with a genuine Kent flue system purchased from your 

authorised Kent retailer. Failure to do so will void your warranty in its entirety. The 

company is not liable for any consequential damage by a failure or defect covered 

in this warranty. All claims against the warranty must be directed in the first instance 

to the retail outlet from which you made your purchase. Any repairs undertaken 

without the express authority of Kent will invalidate this warranty. This warranty does 

not cover damage caused by wetbacks/water boosters, burning improper fuels 

(driftwood/treated wood/coal or plastic-based waste), or installation, plumbing and 

sweeping work done by others (the installer is liable for any incorrect procedures or 

poor workmanship). 

 

 

Transferability: 

 

Your Kent wood burner warranty is transferable on the sale of the home where the 

wood burner is installed. Nothing in this warranty is intended to limit any conditions of 

the warranty right or remedy pursuant to the Consumer Guarantee Act 1993, except 

to the extent permitted under the Act. Your Kent wood burner is intended for 

domestic use only and the warranty is not valid for wood burners to be used for 

business purposes. Kent reserves the right to alter or amend specifications or designs 

of its product without prior notice. 

 

KENT WARRANTY  

REGISTRATION 

 

Please keep this copy for your records. 

 

MODEL:…………………………………………………............................ 

 

SERIAL NUMBER:…………………………………………………………… 

 

RETAILER:……………………………………………………………………. 

 

PURCHASE DATE:………………………………………………………….. 

 

INVOICE NUMBER:……………………………………............................ 

(Please keep your invoice attached to your warranty record). 

 

INSTALLER NAME:…………………………………….……………………. 

 

DATE INSTALLED:…………………………………………………………... 

 

NZ HOME HEATING  

ASSOCIATION NUMBER:………………………….………………………. 

 

INSTALLER SIGNATURE:…………………………………………………… 

 

 

 

FreePost KENT

 

Aber Holdings Ltd

 

PO Box 10095

 

Te R

apa

 

Hamilton 3241

 

 

KEEP THIS IN A SAFE PLACE FOR FUTURE REFERENCE. 

 

Distributed by: 

Aber, Hamilton, NZ 

www.aber.co.nz 

 

3634-03/13 

EASY ONLINE OPTION 

Go to www.kent.co.nz to 

complete your registration 

online. Quick and easy for 

complete peace of mind. 

 