Note:
If at any time the power button is operated during Thermostat mode, the
control will cancel any thermostat operation and return the control to manual
mode.
Note:
As stated in an earlier section, snooze function can also be operated in
conjunction with thermostat mode. The thermostat symbol and the Zzz symbol
will be on together when in this mode.
Lighting the Fire with the Manual Switch Panel
Note: Normal operation is via the handset only. Due to the design of
the FR920HE it is not possible to use the manual switches on the gas
control during normal operation. Use these instructions during
installation and commissioning.
To start the fire, press the power button and hold for 1 second then release.
The burner will then light within 10 seconds and adjust automatically to the
maximum power setting. The power of the burner can then be adjusted up and
down by pressing the (–) and (+) buttons – never press the buttons at the
same time or the fire will lose its memory and need setting back to the factory
settings.
Replacing the Batteries
Handset Batteries.
To replace the handset batteries open the cover on the back of the handset.
Remove the old batteries and using the diagram on the inside of the cover fit
new high quality alkaline batteries.
Main Appliance Batteries
These are inside the gas fire body. To change the
batteries involves removal of the vanity cover and
heat shields. It is strongly advised to leave this
task to a gas safe engineer to perform. The best
time to change the batteries is during the annual
service of the fire.
Step 1 :
Remove the glass by following the steps
shown on page 9.
Step 2 :
Remove the vanity Cover by following the
steps on page 12.
Step 3 :
Remove the heat shield from the gas
control. This is a special sleeve that is over the gas
control. It must be replaced.