Page 40 of 60
Spirit Fires Limited. 4 Beaumont Square, Aycliffe Industrial Park, Newton Aycliffe, County
Durham, DL5 6XN. Tel : 01325-327221 Web :
www.spiritfires.co.uk
Service and Aftercare Requirements
Every 12 months the gas fire unit should undergo a regular service; this work
should be carried out by a Gas Safe registered engineer only.
The annual service of the unit must be performed in line with the
instructions in the manual. Refer to the enclosed technical installation
and operational manual & the remote control instruction document.
When carrying out the annual service, the Gas Safe Engineer should
examine and verify the following;
•
Ensure the pilot assembly is clean and
operates safely.
•
Ensure the injector is clean and fitted
correctly.
•
Ensure the burner aeration is as per the
manufacturer’s instructions.
•
That the gas fire burner unit correctly
cross-lights within 10 seconds.
•
A pressure drop test to verify that there
are no gas leaks
•
That the electronic ignition system
operates correctly
•
That the burner surface is free from damage and debris.
•
Ensure the chimney is operating correctly by performing a flue test.
•
Ensure that any debris in the chimney void is cleared (BS7977 version)
•
That the owner has a copy of the installation and operation manual
For Spare Parts please call 01325-327221 and ask for customer
service.
Spare parts are not returnable & Spirit Fires cannot accept
responsibility for incorrect parts being ordered.
When ordering
replacement components or requesting technical assistance, you should at all
times quote the following:
•
Type of fire & gas type (LPG or NG) as shown on Data Plate
•
Unit serial number as shown on Data Plate or front of booklet.
•
Component part number or description of fault