Page 3 of 60
Spirit Fires Limited. 4 Beaumont Square, Aycliffe Industrial Park, Newton Aycliffe, County
Durham, DL5 6XN. Tel : 01325-327221 Web :
www.spiritfires.co.uk
Technical Data
Approval EN613
:
2001
Approval
BS7977 : 2009
Pilot Assembly Marking
ERTA-82-650 [AC012]
Injector
82-600 (AC061)
x1pc
Gas connection
8mm O.D. tube
Minimum flue diameter
125.0mm
Minimum flue height
2.0m
Room Ventilation [PAV]
Not Required
Approximate weight
25kg
Gas Type*
G20 – I
2H
– Natural Gas
Gas Pressure
20mBar
Nominal Heat Input
6.1 kW, Gross
Gas Flow Rate
0.581m3/hour
Nox Class
Class 5
Efficiency Class
Class 2
Efficiency Rating [Net]
77.7%
Efficiency Rating [Gross] SAP
70.0%
When replacing the Injector or Pilot assembly this must be purchased from the
manufacturer. Review the sections in the booklet relating to replacement parts
by the user and qualified installer.
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in
EN
613:2001 - Independent gas-fired convection heaters.
The Gross calorific
value of the fuel has been used for this efficiency calculation. The test data
from which it has been calculated has been certified by Gastec at CRE Limited
[notified body number 0558]. The efficiency value may be used in the UK
Government’s Standard Assessment Procedure (SAP) for energy ranging of
dwellings