Page 41 of 60
Spirit Fires Limited. 4 Beaumont Square, Aycliffe Industrial Park, Newton Aycliffe, County
Durham, DL5 6XN. Tel : 01325-327221 Web :
www.spiritfires.co.uk
Servicing Instructions
The following servicing procedure should be carried out every 12 months and
only by a registered Gas Safe Engineer. As foreign bodies, which can gather on
the surface of the burner unit, it is inevitable that servicing can be a dusty
operation therefore suitable precautions should be taken.
Warning:
The pilot assembly and flame sensing device fitted to this fire is also
an atmosphere sensing device. If for any reason any part of the pilot assembly
is to be replaced, the entire assembly including the pilot burner, thermocouple
electrode and injector must also be exchanged. This atmosphere sensing
device is not adjustable and must not be disabled
. Only manufacturer
supplied parts must be used when replacing components on this fire.
Servicing Procedure
•
Turn off the gas fire and allow time for it to cool.
•
Remove the vanity cover as shown on page 12.
•
Turn off the gas supply at the isolation tap within the fire.
•
INJECTOR:
Use a 15mm spanner to remove the gas pipe from the
injector. Using a 7mm spanner loosen the screws on the injector bracket
and lift the injector bracket off the venturi tube. Clean the injector and
remove blockages. Do not use a needle or wire, as this will damage the
injector. Reassemble the injector and connect the gas pipe. To get the
correct aeration the injector bracket must be flush with the venturi tube
before securing the 7mm nuts.
•
PILOT ASSEMBLY:
To ensure a long reliable life it is advised to change
the pilot when servicing the fire. This can be done by disconnecting the
gas supply, ignition lead and connections to the remote. Use the image
below to ensure the correct connections are made on the remote black
box. If the pilot is not being changed then make sure the pilot journals
are clear and free from dirt.